Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add filters








Year range
1.
Chinese Journal of Medical Imaging ; (12): 885-888, 2017.
Article in Chinese | WPRIM | ID: wpr-706422

ABSTRACT

Purpose To explore the feasibility of dual source CT virtual unenhanced replacing conventional plain scan in parotid gland mass examination.Materials and Methods Thirty-five parotid gland mass (38 focus) confirmed through dual source CT and surgical operative pathology in the First Affiliated Hospital of Kunming Medical University were retrospectively analyzed,including 13 pleomorphic adenoma parotid,14 adenolymphoma (17 focus),5 malignant tumor and 3 inflammatory lesions.All patients received conventional plain scan and dual energy enhanced scan.Liver virtual unenhanced software was adopted to obtain virtual unenhanced image in arterial phase and concordance of parotid gland mass displayed on conventional plain scan and virtual unenhanced images was compared.Normal parotid tissue,focal area,salivary gland,thoracic paraspinal muscle,average CT value of lower jawbone,signal noise ratio noise ratio (SNR),contrast noise ratio noise ratio (CNR),image quality score,radiation dose and effective dose (ED) for conventional plain and virtual unenhanced were compared.Results Subjective image quality score for conventional plain scan and virtual unenhanced was 4.34 ± 0.80 and 4.17 ± 0.82,respectively;and difference between the two was of no statistical significance (P>0.05).Average CT value difference of angulus mandibulae thoracic paraspinal muscle,submandibular gland and normal parotid for 35 patients with parotid space-occupying lesions with conventional plain scan and virtual plain scan was of no statistical difference (P>0.05).The average CT value of conventional plain scan parotid mass and mandible compared with the virtual plain scan,the difference was statistically significant (P<0.05).SNR difference for parotid gland mass was of statistical significance (P<0.05).Difference of CNR between the two groups was of no statistical significance (P>0.05).ED of virtual plain scan was lower than that of conventional plain scan and the difference was of statistical significance (P<0.05).The reduced radiation dose was about 38.6%.Conclusion Conventional plain scan and virtual unenhanced are of highly concordance in examination and diagnosis of parotid gland mass and radiation dose for virtual unenhanced is less.

2.
Chinese Journal of Medical Imaging ; (12): 662-665,670, 2017.
Article in Chinese | WPRIM | ID: wpr-706382

ABSTRACT

Purpose To explore the clinical value of iodine content and energy spectrum in dual-source dual-energy CT scan in the diagnosis of inflammatory bowel disease reactive hyperplasia lymph nodes (LNs) and metastatic LNs in patients with colorectal cancer.Materials and Methods Complete dual energy scanning data of 51 reactive LNs in 30 patients with inflammatory bowel disease (15 cases of ulcerative colitis,15 cases of Crohn's disease) and 35 metastatic LNs in 20 patients with colorectal cancer confirmed by colonoscopy or pathology were collected and retrospectively analyzed.The iodine contents of reactive hyperplasia LNs and metastatic LNs were detected and the slopes of energy spectrum curves were compared between the two different pathological LNs.Moreover,the receiver operating characteristic curve was applied to determine the optimum sensitivity and specificity of differential diagnosis of these two kinds of LNs.Results The iodine contents of inflammatory bowel disease reactive hyperplasia LNs and metastatic LNs in patients with colorectal cancer in arterial phase were (2.66±0.70) mg/ml and (1.65± 0.81) mg/ml,and the slopes of curves were 2.81 ±0.56 and 0.14±0.09,respectively.There were significant differences in the iodine contents and the slopes of the energy spectral curves between these two kinds of LNs in arterial phase (P<0.05).Moreover,the diagnostic efficacy of energy spectrum curve slope,of which the sensitivity,specificity and area under the curve was 96.7%,76.7% and 0.846,respectively;was higher than those of iodine content in diagnosing inflammatory bowel disease reactive hyperplasia LNs and metastatic LNs.Conclusion Dual-source dual-energy CT-derived arterial phase measurement of iodine content and slope of energy spectral curve has certain significance for differential diagnosis of inflammatory bowel disease reactive hyperplasia LNs and metastatic LNs,and the slope of spectral curve is superior to iodine.

3.
Chinese Journal of Medical Imaging Technology ; (12): 863-867, 2017.
Article in Chinese | WPRIM | ID: wpr-619723

ABSTRACT

Objective To investigate the diagnostic value of dual energy CT for small central cervical metastatic lymph nodes in patients with papillary thyroid cancer.Methods The data of 43 patients with thyroid papillary carcinoma confirmed by pathology were retrospectively analyzed.All of the patients underwent dual energy CT scan before operation.The short diameter,iodine concentration and normalized iodine concentration (NIC) of enhanced arterial and venous phases and the slope of the energy spectrum curve were analyzed between metastatic central cervical lymph nodes and non-metastatic lymph nodes.ROC curve was used to analyze the diagnosis efficacy of iodine concentration and NIC for metastatic lymph nodes of thyroid carcinoma.Results Totally there were 119 lymph nodes in 43 patients included 55 thyroid papillary carcinoma metastasis lymph nodes (metastasis group) and 64 non-metastatic lymph nodes (non-metastasis group).There was significant differences of the mean short diameter of the lymph nodes between the two groupos (t=-2.20,P=0.03).In arterial phase,the average iodine concentration of metastasis group and non-metastasis group were (2.93±1.62)mg/ml and (2.17±1.09)mg/ml;the NIC were 0.33±0.21 and 0.19 ± 0.12;and the slope of the energy spectrum curve were 0.79±0.43 and 0.63±0.37 respectively.In venous phase,the average iodine concentration of metastasis group and non-metastasis group were (2.68± 1.54) mg/ml and (2.17 ± 1.01) mg/ml;the NIC were 0.51 ± 0.18 and 0.43 ± 0.15;the slope of the energy spectrum curve were 0.54 ± 0.42 and 0.62 ± 0.39 respectively.The iodine concentration and NIC in both phases and the slope of spectrum curve in arterial phase had statistical differences between the metastasis and non-metastasis groups (all P<0.05).ROC curve showed that the area under the curve (AUC) of iodine concentration and NIC in the diagnosis of metastatic lymph nodes were 0.62 and 0.73 in arterial phase,respectively.And the AUC of iodine concentration and NIC were 0.61 and 0.63 in venous phase,respectively.Conclusion There are differences of iodine concentration,NIC in arterial and venous phases and curve slope in arterial phase of dual-energy between malignant and benign central cervical lymph nodes in thyroid papillary carcinoma.Dual energy CT technology is helpful in identifying of metastatic from non-metastatic small central cervical lymph nodes.

4.
Chinese Journal of Medical Imaging ; (12): 161-164, 2015.
Article in Chinese | WPRIM | ID: wpr-460785

ABSTRACT

PurposeTo explore the significance of dual energy CT in differential diagnosis of squamous cell carcinoma metastatic lymph nodes and lymph node tuberculosis in the neck.Material and Methods Twenty-five patients with a total of 62 cervical enlarged lymph nodes confirmed with squamous cell carcinoma metastasis or lymph node tuberculosis by pathology underwent dual energy enhanced CT scan. Iodine coverage value of two different kinds of pathological properties of lymph nodes was measured. The trend of the spectrum curve was observed and the energy spectrum curve slope of two kinds of lymph nodes were compared. The sensitivity, specificity and accuracy of energy spectrum curve slope in differential diagnosis were analyzed. Results Of all 62 lymph nodes, there were 32 squamous cell carcinoma metastatic lymph nodes and 30 lymph node tuberculosis. There were statistic significance in the iodine coverage between the squamous cell carcinoma metastatic lymph nodes and lymph node tuberculosis (t=3.806 and 3.698,P<0.05). In the range from 60 keV to 180 keV, CT value of the two kinds of lymph nodes decreased with increase of keV value. It showed the higher the keV value the less CT value decreased, with the energy spectrum curve of drop type. The area of the iodine coverage was 0.756 with the differential diagnostic sensitivity of 56% and the specificity of 80%. The area of energy spectrum curve slope was 0.898 with the differential diagnostic sensitivity of 76% and the specificity of 85%.Conclusion The iodine coverage value and the energy spectrum curve slope have significance in differential diagnosis of the cervical squamous cell carcinoma metastatic lymph nodes and lymph node tuberculosis. The energy spectrum curve slope is superior to the iodine coverage value in differential diagnosis.

5.
Journal of Practical Radiology ; (12): 740-743,758, 2015.
Article in Chinese | WPRIM | ID: wpr-600700

ABSTRACT

Objective To explore the value of spectral imaging technique in dual-energy CT in differential diagnosis of the metastatic lymph nodes in thyroid carcinoma,squamous cell carcinoma metastatic lymph nodes and lymphoma in the neck.Methods In 30 patients with pathologically confirmed with a total of 79 cervical lymph nodes enlargement which were using dual energy scan .Then observed the change trend of the spectrum curve and comparison the three kinds of lymph node energy spectrum curve’s slope.Results In the 79 lymph nodes,the metastatic lymph nodes in thyroid carcinoma were twenty-three,squamous cell carcinoma metastatic lymph nodes were twenty-four and lymphoma were thirty-two.From 60 to 180 keV,with the increase of keV values,the three kinds of malignant lymph nodes of the corresponding CT value decreasing and the higher the keV value,the CT value decrease magnitude was small,and the spectrum curve was〞drop type〞.The slope spectrum curve of the metastatic lymph nodes of thyroid carcinoma in arterial phase and parenchymal phase were maximum,which were 1.23±0.41 and 0.85±0.33,respectively.The slope spectrum curve of lymphoma in arterial phase and parenchymal phase were least,whcih were 0.40±0.16 and 0.47 ±0.09.The slope spectrum curve of the squamous cell carcinoma metastatic lymph nodes in arterial phase and parenchymal phase were 0.88±0.10 and 0.62±0.28.The energy spectrum curve slope of the three kinds of malignant lymph nodes have statistical significance.Conclusion The energy spectrum curve slope of arterial phase and parenchymal phase has some significance lymph node metastasis of in thyroid carcinoma,the metastatic lymph nodes and lymphoma in the neck.

6.
Journal of Practical Radiology ; (12): 580-583,612, 2014.
Article in Chinese | WPRIM | ID: wpr-598966

ABSTRACT

Objective To investigate the diagnostic value of cervical metastatic lymph nodes by T1 perfusion-weighted imaging and analyse the effect of age on perfusion.Methods 18 cases of cervical lymph node metastasis (case group)and 30 healthy people (control group)were performed T1 perfusion-weighted imaging.The semi-quantitative parameters (including in maximum relative enhancement ratio,wash in rate,wash out rate and peak time)and time-intensity curve (TIC)were compared between case group and control group.Moreover,the effect of age on perfusion was investigated by the age of 40 years old.Results The inflow rate was statistically significant difference between the two groups (P0.05).The time-intensity curve in metastatic lymph nodes and normal lymph nodes were common in typeⅡ. The maximum relative enhancement ratio and wash in rate negatively correlated with the age and the maximum relative enhancement ratio and wash in rate below the age of 40 years old were higher than above the age 40.Conclusion The wash in rate is helpful to dif-ferentiate metastatic lymph nodes and normal lymph nodes.The effect of age on perfusion is considered.

7.
Chinese Journal of Medical Imaging ; (12): 812-815, 2013.
Article in Chinese | WPRIM | ID: wpr-439716

ABSTRACT

Purpose To investigate the value of dual-source CT with dual-energy virtual non-contrast imaging in the diagnosis of cervical lymph node disease. Materials and Methods The dual-energy scan data of 126 lymph nodes from 50 patients confirmed pathologically were reviewed. The difference of average CT value, signal to noise ratio, contrast to noise ratio, image subjective assessment and lesion detectability between virtual non-contrast imaging and conventional non-contrast scan were analyzed. The radiation dose of virtual non-contrast imaging and real non-contrast imaging of cervical lymph node were also compared. Results ①The consistency of virtual plain scan combined with dual-energy contrast imaging in the diagnosis of six typical pathological types were all satisfactory (Kappa>0.7, P0.05).③ Compared with conventional enhanced scan, dual-energy phases reduced radiation dose by about 19%. Conclusion Dual-energy virtual non-contrast imaging combined with contrast imaging can provide clear images in the diagnosis of enlarged cervical lymph nodes and reduce radiation dose of subjects, thus can be expected to replace real scan.

8.
Chinese Journal of Medical Education Research ; (12): 839-840, 2011.
Article in Chinese | WPRIM | ID: wpr-421278

ABSTRACT

Test is an important way for getting feedback from students about teaching. The traditional examination is not suitable for the requirements of modernization teaching.Web-Based Course Examination of practice pathology simplifies the process of traditional examination greatly. It is one of the important means in modernization teaching.

9.
Chinese Journal of Medical Education Research ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-624476

ABSTRACT

A well Web-based teaching supplementary system is beneficial for saving teaching resources,arousing students’enthusiasm for study.but there is no the emotion exchange between teachers and students which exists in traditional class.Web-based supplementary teaching is an important supplementary method for medical morphology courses,but it can not replace the traditional teaching method.Combining them each other is needed for raising teaching quality.

10.
Journal of Practical Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-541481

ABSTRACT

Objective To improve the diagnosis and treatment of pulmonary lymphangiomyomatosis (PLAM). Methods The clinical data of 1 PLAM case in our hospital was analysed, along with a review of the related literatures.Results PLAM was a rare diffuse interstitial plumonary disease of unknown cause, which was oiraracterized by recurrent spontaneous pneumothorax shortness of breath (dyspnea) with physical activity, haemopthsis and chylothorax. Radiological appearances were extensive bilateral linear pattern, and honeycomb pattern in the end. High resolution CT scan (HRCT) showed multiple thin walled cysts distributed evenly throughout the bilateral lung fields with normal intervening lung parenchyma. Pathological characters were abnormal, pervasice multiplication of smooth muscle of cell in and around the small airway, lymphatic and small blood vessels. Immunohistochemical test showed HMB45(+).Conclusion It should be considered the probability of PLAM when women of childbearing ages have some clinical manifestations as follows, the increasing dyspnoea that can not be relieved similar to emphysema, high- resolution CT scan (HRCT) shows multiple thin walled cysts distributed evenly throughout the bilateral lung fields with normal intervening lung parenchyma, and recurrent pneumothorax or chylothorax. The optimal confirm diagnostic method is lung tissue biopsy.

11.
Journal of Practical Radiology ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-539569

ABSTRACT

Objective To discuss the clinical values of virtual endoscopy (VE) using multislice computed tomography (MSCT) in diagnosis of the aorta and iliac artery diseases.Methods MSCT angiography in 36 cases suspected of the aorta and iliac artery diseases and 40 cases underwent abdominal examination were performed, then all CT virtual endoscopy (CTVE) were obtained at the vessel with suspected lesions on work-station, and the relations between the quality of images and scanning parameters were observed.Results All internal and dual-cavity were seen in 10 cases of aortic dissection; enlarged cavity of aneurysm were showed in 16 aortic aneurysms. Calcification plaques were displayed in 48 cases. One endograft and one postoperative aorta were seen the morphology and the location of stenosis. One case of iliac artery obstruction was displayed obstructive cavity on the image of CT virtual endoscopy.Conclusion The quality of CT virtual endoscopy is related to the scanning technique,scanning parameters, motion aritiact. CT vitrtual endoscopy is the important complementary to maximum intensity projection, multiplannar reformation, surface shadow display, and axial images, and has high value in the diagnosis, treatment, and follow-up of the aortic diseases

12.
Journal of Practical Radiology ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-540376

ABSTRACT

Objective To assess the value in detecting the tracheobronchial tree invasion by central lung cancer (CLC)using MSCT axial images and 4 kinds of images post-processed techniques.Methods 38 cases with CLC identified by fibrobrochoscopy or operation were scanned using MX8000 scanner with slice thickness of 3.2 mm, overlapping interval of 1.6 mm, pitch of 1.0. Multiplanar reformation(MPR), shaded surface display(SSD), volume rendering (VR) and virtual endoscopy(VE) were performed in all cases. Two radiologists assessed the invasion of tracheobronchial tree by CLC together.The imaging findings were compared with the data of surgery in 12 cases who were undergone operation.Results 38 cases of CLC, 0 grade to Ⅳ grade were assessed in 0,8,14,11 and 5 cases respectively by MSCT axial images, while in 0,10,11,12 and 5 cases by MSCT post-processing images. The concordance rate was 75% for MSCT axial images(n=9), and 100% for MSCT post-processing images(n=12) among 12 cases performed operation(? 2 test,? 2=6.0,P

SELECTION OF CITATIONS
SEARCH DETAIL